RD 27 Maintenance
wc_tx000815gb.fm 63
Continued from the previous page.
6. Install the new primary air filter element.
7. Replace the cover (b). Position it so that the breather (d) is not obstructed.
8. Reset the filter indicator (a).
5.9 Testing the Backup Alarm
Background
The backup alarm is located on the rear of the machine.
When
Every 10 hours of service or daily
Testing
Procedure
Follow the procedure below to test the backup alarm.
1. Turn the starting key to POSITION 1.
2. Move the forward/reverse lever to the reverse position.
The backup alarm should sound immediately. The backup alarm will continue to
sound until the forward/reverse lever is moved to the NEUTRAL position or to the
FORWARD position.
NOTICE: If the backup alarm does not sound, make the necessary repairs before
using the machine.