June 2014
3-8
Xerox® WorkCentre® 3025 Multifunction Printer Service Manual
IQ7, IQ8
Image Quality
Figure 1 Uneven Density
IQ8 Background RAP
Uniform toner contamination appears in most or all non-image areas of the printed sheet (Fig-
ure 1).
Initial Actions
• Check that media type settings are correct.
• Check that the paper meets specifications. Refer to Section 6 for product specifications.
• Check the life of the Print Cartridge, refer to GP 2 Machine Status and Reports.
Replace the Print Cartridge if it is at end of life. Refer to the Workcentre® 3025 User
Guide, Section 6 Maintenance, General Care, for detailed instructions on how to replace
the Print Cartridge.
Procedure
• Switch off the power.
• Clean the contacts on the Print Cartridge and the LVPS / HVPS PWB.
• Switch on the power and make a test print.
The test print looks OK.
YN
Replace the LVPS / HVPS PWB; (REP 1.6), PL 5.1.
Go to Call Closeout.
Figure 1 Background