4
Parameter Copy Mode
4.2 Operations
4-9
4.2.3 Verify Parameters (VERIFY)
The parameters of the selected block saved in the digital operator and those in the
SERVOPACK are verified, and the result is displayed.
(1) Operating Procedure
Step Display after Operation Keys Operation
1
Open the parameter copy mode menu
display, and select “VERIFY” using the
or Key.
The blinking menu is one that is being
selected.
2
Press the
Key.
The display changes to the parameter
block selection display.
3
Press the
or Key to select
a parameter block (00 to 06) of the digi-
tal operator that is to be compared with
the SERVOPACK parameters.
4
Press the
Key.
The display changes to the execution dis-
play.
5
Press the Key to start verifying
parameters.
Note: Not to execute verifying, press the
Key. The display returns to
the parameter block selection dis-
play.
1:SERVO OP
2:OP SERVO
3:VERIFY
4:LIST
BB COPY
00:SGDV R70
01:∗∗∗∗
02:∗∗∗∗
03:∗∗∗∗
BB VERIFY
00:SGDV R70
01:∗∗∗∗
02:∗∗∗∗
03:∗∗∗∗
BB VERIFY
00:SGDV R70
Start : [READ]
Return: [MODE]
BB VERIFY
00:SGDV R70
Reading
Parameters..
<< OP >>
BB OP SERVO

Table of Contents

Other manuals for YASKAWA E-7 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA E-7 Series and is the answer not in the manual?

YASKAWA E-7 Series Specifications

General IconGeneral
BrandYASKAWA
ModelE-7 Series
CategoryServo Drives
LanguageEnglish

Related product manuals