20 Troubleshooting
124 YASKAWA TOEPC7106171FD FP605 DRIVE INSTALLATION & PRIMARY OPERATION
Code Name Causes Possible Solutions
oPE03 Multi-Function Input Setting Err
The settings for these parameters do not agree:
F3-10 to F3-25 [Terminal D1 to DF Function
Selection]
H1-01 to H1-08 [Terminals S1 to S8 Function
Selection]
H7-01 to H7-04 [Virtual Multi-Function Inputs 1
to 4]
Correct the parameter settings.
oPE05 Run Cmd/Freq Ref Source Sel Err
The setting to assign the Run command or frequency
reference to an option card or the pulse train input is
incorrect.
Correct the parameter settings.
oPE07 Analog Input Selection Error
The settings for H3-02, H3-06, H3-10 [MFAI
Function Selection] and H7-30 [Virtual Analog Input
Selection] overlap.
Set H3-02, H3-06, H3-10, and H7-30 correctly to prevent overlap.
Note:
It is possible to set these functions to multiple analog input
terminals at the same time:
Setting value 0 [Frequency Reference]
Setting values F and 1F [Not Used]
oPE08 Parameter Selection Error
You set a function that is not compatible with the
control method set in A1-02 [Control Method
Selection].
1. Push to show U1-18 [oPE Fault Parameter], and find
parameters that are not in the applicable setting range.
2. Correct the parameter settings.
Note:
If more than one error occurs at the same time, other oPExx
errors have priority over oPE02.
oPE09 PID Control Selection Fault
These parameters are set at the same time:
b5-01 = 1
b5-11 = 1 [PID Output Reverse Selection =
Negative Output Accepted]
And one of these parameters is set:
d2-02 0.0 [Frequency Reference Lower Limit
0.0%]
Y1-06 0.0 [Minimum Speed 0.0%]
Y4-12 0.0 [Thrust Frequency 0.0%]
Y1-01 0 [Multiplex Mode Drive Only]
YF-01≠ 0 [PI Aux Control Selection Disabled]
Correct the parameter settings.
oPE10 V/f Data Setting Error
The parameters that set the V/f pattern do not satisfy
these conditions:
For motor 1: E1-09 E1-07 < E1-06 E1-11
E1-04 [Minimum Output Frequency Mid Point A
Frequency < Base Frequency Mid Point B
Frequency Maximum Output Frequency]
For motor 2: E3-09 E3-07 < E3-06 E3-11
E3-04 [Minimum Output Frequency Mid Point A
Frequency < Base Frequency Mid Point B
Frequency Maximum Output Frequency]
Set the parameters correctly to satisfy the conditions.
oPE11 Carrier Frequency Setting Error
These parameters are set at the same time:
C6-05 > 6 [Carrier Freq Proportional Gain > 6]
C6-04 > C6-03 [Carrier Frequency Lower Limit
> Carrier Frequency Upper Limit]
Note:
When C6-05 < 7, C6-04 becomes disabled. C6-
03 stays active.
Set C6-02 to C6-05 correctly.
oPE16 Energy Saving Constants Error
The Energy Saving parameters are not set in the
applicable setting range.
Make sure that E5-xx is set correctly as specified by the motor
nameplate data.
oPE33 Digital Output Selection Error
These two parameters are set at the same time:
H2-60 F [Term M1-M2 Secondary Function
Not Used]
H2-01 = 1xx [Term M1-M2 Function Selection =
Inverse output of xx]
Clear the H2-01 to H2-03 = 1xx [Inverse output of xx] settings.
Note:
It is not possible to set H2-01 to H2-03 = 1xx [Inverse output of
xx] when using output functions for logic operations (H2-60,
H2-63, H2-66 F).
Auto-Tuning Errors
This table gives information about errors detected during Auto-Tuning. If the drive detects an Auto-Tuning error, the
keypad will show the error and the motor will coast to stop. The drive will not send notification signals for faults and
alarms when Auto-Tuning errors occur.
Two types of Auto-Tuning errors are: Endx and Erx. Endx identifies that Auto-Tuning has successfully completed
with calculation errors. Find and repair the cause of the error and do Auto-Tuning again, or set the motor parameters
manually. You can use the drive in the application if you cannot find the cause of the Endx error.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA FP65U T Series and is the answer not in the manual?

YASKAWA FP65U T Series Specifications

General IconGeneral
BrandYASKAWA
ModelFP65U T Series
CategoryDC Drives
LanguageEnglish

Related product manuals