10 Drive Start-Up Procedure
60 YASKAWA TOEPC7106171FD FP605 DRIVE INSTALLATION & PRIMARY OPERATION
Output Terminals
Refer to Table 10.2 and Table 10.3 for a list of output terminals and functions.
Table 10.2 Control Circuit Output Terminals
Type Terminal Name (Default) Function (Signal Level)
Fault Relay
Output
MA
N.O. output
(Fault)
Drive Fault Signal Output
Relay output
30 Vdc, 10 mA to 2 A
250 Vac, 10 mA to 2 A
Minimum load: 5 V, 10 mA (Reference value)
MB
N.C. output
(Fault)
MC Digital output common
MFDO
M1
MFDO
(During Run)
Multi Function Digital Output
Relay output
30 Vdc, 10 mA to 2 A
250 Vac, 10 mA to 2 A
Minimum load: 5 V, 10 mA (Reference value)
Note:
Do not set functions that frequently switch ON/OFF to MFDO (M1 to M4) because this will
decrease the performance life of the relay contacts. Yaskawa estimates switching life at
200,000 times (assumes 1 A, resistive load).
M2
M3
MFDO
(Zero Speed)
M4
MD
N.O. output
(Speed Agree 1)
Multi Function Digital Output
Relay output
30 Vdc, 10 mA to 2 A
250 Vac, 10 mA to 2 A
Minimum load: 5 V, 10 mA (Reference value)
ME
N.C. output
(Speed Agree 1)
MF Digital output common
Table 10.3 Control Circuit Monitor Output Terminals
Type Terminal Name (Default) Function (Signal Level)
Monitor Output
FM
MFAO 1
(Output frequency)
Multi Function Analog Output
Select voltage or current output.
0 V to 10 V/0% to 100%
4 mA to 20 mA (receiver recommended impedance: 250 Ω)
Note:
Select with jumper switch S5 and H4-07 [Terminal FM Signal Level Select] or H4-08
[Terminal AM Signal Level Select].
AM
MFAO 2
(Output current)
AC Monitor common 0 V
External Power
Supply Output
+P External power supply
Power supply for external devices.
24 V (150 mA maximum)
External Power Supply Input Terminals
Refer to Table 10.4 for a list of the functions of the external power supply input terminals.
Table 10.4 External Power Supply Input Terminals
Type Terminal Name (Default) Function
External Power Supply Input
Terminals
PS External 24 V power supply input
Supplies backup power to the drive control circuit, keypad, and option board.
21.6 VDC to 26.4 VDC, 700 mA
AC External 24 V power supply ground 0 V
Serial Communication Terminals
Refer to Table 10.5 for a list of serial communication terminals and functions.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA FP65U T Series and is the answer not in the manual?

YASKAWA FP65U T Series Specifications

General IconGeneral
BrandYASKAWA
ModelFP65U T Series
CategoryDC Drives
LanguageEnglish

Related product manuals