5IM 04L41B01-02E
Checking the Contents of the Package
Unpack the box and check the contents before operating the
instrument. If some of the contents are not correct or missing or if
there is physical damage, contact the dealer from which you
purchased them.
DX
A name plate is located on the top panel of the DX (side panel on
models with the /H5[ ] option). Check that the model name and
suffix code given on the name plate on the rear panel match those
on your order.
name plate
D
I
S
P
/
E
N
T
E
R
6
9
7
8
1
0
1
1
12
1
2
3
4
5
1
00
-
24
0
V A
C
5
0/
6
0H
z
1
0
0
V
A
MAX
N
L
MODEL
FREQUENCY
NO.
SUFFIX
SUPPLY
STYLE
H
S
Made in China
CUS
172608
N200
R
NO. (Instrument Number)
When contacting the dealer from which you purchased the
instrument, please give them the instrument number.
MODEL and SUFFIX Code
Model code Suffix code
-1
-2
-4
-2
Daqstation DX1000 2ch, 125ms (25ms
*12
)
Daqstation DX1000 4ch, 125ms (25ms
*12
)
Daqstation DX1000 6ch, 1s (125ms
*12
)
Daqstation DX1000 12ch, 1s (125ms
*12
)
Daqstation DX1000N 2ch, 125ms (25ms
*12
)
Daqstation DX1000N 4ch, 125ms (25ms
*12
)
Daqstation DX1000N 6ch, 1s (125ms
*12
)
Daqstation DX1000N 12ch, 1s (125ms
*12
)
Standard Memory
Large Memory
CF card (with medium)
English, degF, DST (summer/winter time)
DX1002
DX1004
DX1006
DX1012
DX1002N
*11
DX1004N
*11
DX1006N
*11
DX1012N
*11
Internal memory
External storage medium
Language
Options
/A1 Alarm output 2 points
*1
/A2 Alarm output 4 points
*1
/A3 Alarm output 6 points
*1*2
/C2 RS-232 interface
*3
/C3 RS-422A/485 interface
*3
/F1 FAIL/Status output
*2
/H2 Clamped input terminal (detachable)
/H5[ ] Desktop type
*4
/M1 Mathmatical functions
/N1 Cu10, Cu25 RTD input/3 leg isolated RTD
/N2 3 leg isolated RTD
*5
/N3 Extended input type (PR40-20, JPt50, etc.)
/R1 Remote control
/TPS2 24VDC transmitter power supply (2 loops)
*6
/TPS4 24VDC transmitter power supply (4 loops)
*7
/KB1 Easy text entry (with input terminal)
*8*9
/KB2 Easy text entry (without input terminal)
*8
/USB1 USB interface
/PM1
Pulse input (including remote control and mathmatical functions)
*10
/CC1 Calibration correction function
Optional
code
Description
*1 /A1, /A2, /A3 cannot be specified together.
*2 /A3 and /F1 cannot be specified together.
*3 /C2 and /C3 cannot be specified together.
*4 /H5[ ] can be specified for only DX1002, DX1004, DX1006, and DX1012.
D: Power cord UL, CSA st’d
F: Power cord VDE st’d
R: Power cord SAA st’d
J: Power cord BS st’d
H: Power cord GB st’d
*5 /N2 can be specified for only DX1006, DX1006N, DX1012, and DX1012N.
*6 In case that /TPS2 is specified, /TPS4, /A2, /A3, or /F1 cannot be specified
together.
*7 In case that /TPS4 is specified, /TPS2, /A1, /A2, /A3, or /F1 cannot be
specified together.
*8 /KB1 and /KB2 cannot be specified together.
*9 In case that /KB1 is specified, remote input terminal (438227) is included.
*10 In case that /PM1 is specified, /A3, /M1, /R1, /TPS2, or /TPS4 cannot be
specified. And combination of /A2, /F1 cannot be specified together.
*11 DX1002N, DX1004N, DX1006N, and DX1012N are Pull Out Models.
*12 Values in parentheses are for the fast sampling mode.
Standard Accessories
The standard accessories below are supplied with the instrument.
Check that all contents are present and undamaged.
9
ID No.
1 2 43
6
7
5
32
MB
8. One of these power cord types is supplied according
to the instrument’s suffix code
/H5F
/H5D
/H5R
/H5H/H5J
No.Name Number/Model Qty. Notes
1 Terminal screws E9655FX 5 spares M4
2 Mounting brackets B9900BX 2 For panel mounting
Except for the /H5[ ]
models.
3 Door lock key B8706FX 2
4 DAQSTANDARD DXA120 1 CD. Software for
for DXAdvanced setting the DX and
displaying data.
5 DX1000/DX1000N
IM 04L41B01-02E
1 A4 size
Operation Guide
(this manual)
6 Manuals for the B8706ZZ 1 CD. Contains the PDF
DX1000/DX1000N/ file of the user’s
DX2000 manual.
7 CF card B9968NM 1 32 MB (The size and
model may change.)
8 Power cord A1006WD 1 Supplied only for
models with the /H5D
option. Maximum rated
voltage: 125 V
A1009WD 1 Supplied only for
models with the /H5F
option. Maximum rated
voltage: 250 V
A1024WD 1 Supplied only for
models with the /H5R
option. Maximum rated
voltage: 250 V