43Access to the internal parts
EN
5.5 Close the doors - Terra 360
Hazardous voltage
Make sure that only qualified persons have access to the door key.
NOTE
There is one unique door key for each EVSE.
In order to close the doors of the EVSE, repeat the operations described in the “Open doors paragraphs” in
reverse order.
5.6 Internal covers on the AC section - Terra 360
C
A
B
To access the AC section, located on the lower front
side, is necessary to remove the lexan protective
barriers:
Unscrew the fastners on the protective barrier (A) and
remove it.
Unscrew the fastners on the protective barrier (B) and
remove it.
NOTE
The protection (B) is not installed by
factory (is supplied and located on the rear
internal side of the EVSE.
Unscrew the fastners on the metallic protective barrier (C)
and remove it. To remove the metal protection, it is necessary
to open the lower door on the left side also.
Once the protections have been removed, it is possible
to fully access the AC section of the EVSE.
HAZARDOUS VOLTAGE
Do not turn on the EVSE without the protective
barriers.