58 3ADW000395R0100 DCS550 Quick guide edisf a58 3ADW000395R0100 DCS550 Quick guide edisf a
Ubicación de los terminales en el convertidor
Macro finder
Macro name
Main
Contactor
ON / OFF
Start/Stop
DI function
Comment DI5 --> ESTOP
DI6 --> Reset
Standard
AC Static
Jog1 --> DI1
Jog2 --> DI2
Ext Fault --> DI 3
Ext Alarm --> DI4
Hardware I/O control x
2-wire DC cont. US
DC Static
Jog1 --> DI1
Jog2 --> DI2
Ext Fault --> DI 3
Main Cont Ack --> DI4
Hardware I/O control x
3-wire DC cont. US
DC Pulse
Fix speed1 --> DI1
Ext Fault --> DI 3
Main Cont Ack --> DI4
Hardware I/O control x
3-wire Standard
AC Pulse
Fix speed1 --> DI1
Ext Fault --> DI 3
Ext Alarm --> DI4
Hardware I/O control x
Torque limit
AC Static
Jog1 --> DI1
Jog2 --> DI2
Ext Fault --> DI 3
Ext Alarm --> DI4
Hardware I/O control
+ Torque limit
x
Manual / Const
AC Pulse
Jog1 --> DI1
Jog2 --> DI2
Direction --> DI 3
SpC - KP, KI --> DI4
Hardware I/O control
select gain
x
Hand / Auto
AC Static
Control select --> DI2
Reference select --> DI2
Direction select --> DI 3
Hardware I/O control
or field bus control
x
Hand / Mot Pot
AC Pulse
Motor pot up --> DI1
Motor pot down --> DI2
Direction select --> DI 3
Reference select --> DI4
Hardware I/O control
Reference hardware or Motor
potentiometer
x
Motor Pot
AC Static
Direction select --> DI 1
Motor pot up --> DI2
Motor pot down --> DI3
Motor pot minimum --> DI4
Hardware I/O control
Reference Motor potentiometer
x
Torque Ctrl
AC Static
OFF2 (coast stop) --> DI1
Torque select --> DI2
Ext Fault --> DI 3
Hardware I/O control
Speed control or Torque
reference
x
Habilitar un macro
Use el
[DCS550Wizard] 2. Macro as-
sistant of DriveWindow Light ò
Para utilizar el navegador de
parámetros, ya sea a tras del
panel de control, DriveWindow,
o DriveWindow Light.
Utilice los siguientes parámetros:
ApplMacro (99.08) =
seleccionar
Applrestore (99.07) =
YES = ejecutar el comando
MacroSel (8.10) =
observando
Nota
Las funciones y las entradas de-
finidos por la macro se pueden cam-
biar s tarde sin restricciones
Nota
Para el diagrama del macro consulte
la gina 91 ...
X2X1 X3 X4 X5
1 1 1 1 1
S5
15
6 9
S3
S2
S4
1
2
1
2
1
2
1
2
D2100
1
D2001
D2002
D1000
1 30
1
2
1
2
S1
1
42
1
2
3
10
11
12
1
82
1
42
1
2
3
7
8
9
DCS550 terminal alloc_c.dsf
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB DCS550-S01 and is the answer not in the manual?

ABB DCS550-S01 Specifications

General IconGeneral
BrandABB
ModelDCS550-S01
CategoryDC Drives
LanguageEnglish

Related product manuals