EasyManuals Logo
Home>ABB>Measuring Instruments>PFEA 113

ABB PFEA 113 User Manual

ABB PFEA 113
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #117 background imageLoading...
Page #117 background image
Tension Electronics PFEA113, User Manual
Section A.6 Optional Units
3BSE029382R0101 Rev C A-13
A.6 Optional Units
A.6.1 Insulation Amplifier PXUB 201
Figure A-6. Insulation Amplifier PXUB 201
Table A-14. Data for Insulation Amplifier PXUB 201
Type Data
Power supply 20 - 253 V AC/DC
AC: 48 - 62 Hz, 2 VA
DC: 1 W
Current consumption 10 mA + external load, at 24 V
Signal range Input Output
0 ± 10 V 0 ± 10 V
0 - 10 V 4 - 20 mA
0 - 5 V 4 - 20 mA
0 ± 10 V 0 ± 20 mA
0 - 5 V 0 - 20 mA
Input resistance 1 M at 10 V input
500 k at 5 V input
Max. load 10 mA for voltage output
500 for current output
Rise time 50 s or 50 ms, selectable
Ripple 10 mV
p-p
Bandwidth (-3 dB) 10 kHz or 10 Hz
Rated insulation voltage 600 V, basic insulation
Insulation test voltage 4 kV
Dimensions (l × w × d) 99 × 12.5 × 111 mm
Weight 150 g
Mounting DIN-rail 35 mm
+
+24 V
+
Input
Output
+24 V