Tension Electronics PFEA113, User Manual
Chapter 3 Commissioning
3-28 3BSE029382R0101 Rev C
3.12.7 Setting Analog Outputs (AO1-AO6)
Figure 3-17. Menus for Analog Outputs (AO1-6)
In menu
Choose U I or OFF, use up and down keys to select:
Off
U (voltage)
I (current) or
PROFIBUS only
FastSetUp
WebTension
Presentation-
Menu
SetNominal-
Load
ServiceMenu
ZeroSet
SetWrapGain
> 5 s
AO 1- AO 6
Miscellaneous
Menu
System-
Definition
ObjectType
DO 1 - DO 4
AI 1 - AI 2
DI
To AO 2
AO 1
FilterSettings
[ZZ]
HighTension
[XXXXXX.X] N
HighOutput
[XX.XX] V
LowOutput
[XX.XX] V
LowTension
[XXXXXX.X] N
LowLimit
[XX.XX] V
HighLimit
[XX.XX] V
FilterSettings
ZZ
HighTension
XXXXXX.X N
HighOutput
XX.XX V
LowOutput
XX.XX V
LowTension
XXXXXX.X N
LowLimit
XX.XX V
HighLimit
XX.XX V
Choose U I or OFF
[ZZ]
ConnectSignals
[ZZ]
Choose U I or OFF
ZZ
ConnectSignals
ZZ
If not “Off”
1
1
1
1
1
V for voltage or mA for current is shown