EasyManuals Logo
Home>ABB>Measuring Instruments>PFEA 113

ABB PFEA 113 User Manual

ABB PFEA 113
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
Tension Electronics PFEA113, User Manual
Chapter 3 Commissioning
3-22 3BSE029382R0101 Rev C
3.12.5 Zero Set
Zero set is used to compensate for load cell zero signal and tare weight.
The zero setting range is ±2 x F
nom
(load cell nominal load).
Zero set menus are described in the following order for:
1. One roll
2. Two rolls
3. Segmented roll
NOTE
Zero set must be done with no web tension applied to the rolls.
Figure 3-12. Zero Set Menus
FastSetUp
WebTension
Presentation-
Menu
SetNominal-
Load
ServiceMenu
ZeroSet
SetWrapGain
> 5 s
AO 1 - AO 6
Miscellaneous
Menu
System-
Definition
ObjectType
DO 1 - DO 4
AI 1 - AI 2
DI
ZeroSet A, B AreYouSure ActionDone
(shown for 1 s.)
To SetWrapGain
1. Zero setting One Roll
3. Zero setting Segmented Roll
ZeroSet C, D AreYouSure ActionDone
(shown for 1 s.)
ZeroSet A, B AreYouSure ActionDone
(shown for 1 s.)
ZeroSet
ZeroSet A, B, C, D AreYouSure ActionDone
(shown for 1 s.)
To SetWrapGain
ZeroSet
To SetWrapGain
ZeroSet
2. Zero setting Two Rolls
ZeroSet A, B, C, D AreYouSure ActionDone
(shown for 1 s.)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB PFEA 113 and is the answer not in the manual?

ABB PFEA 113 Specifications

General IconGeneral
BrandABB
ModelPFEA 113
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals