Tension Electronics PFEA113, User Manual
Section D.8 Mounting the Load Cells
3BSE029382R0101 Rev C D-9
D.8 Mounting the Load Cells
1. Mount the bearings in the load cells.
NOTE
Use tools and materials that not will damage the bearing or the load cell.
NOTE
One of the bearings is locked in position with retaining rings while the
other bearing is only pressed into the correct position to allow axial expansion.
a. Mount one of the retaining rings into the load cell.
b. Arrange a counterstay as shown in the figure below.
c. Press the bearing to correct position.
NOTE
The bearing bed has only a slight interference fit, and, therefore, no heavy forces
should be used.
d. Mount the other retaining ring into the load cell.
Fixed bearing
with distance rings
Press on the outer ring
Fixed bearing
without distance rings
Loose bearing
Counter stay
Counter stay Counter stay
Press on the outer ring
Distance ring
Retaining ring