Page #192 background imageLoading...
Page #192 background image
Tension Electronics PFEA113, User Manual
Appendix E PFTL 101 - Designing the Load Cell Installation
E-10 3BSE029382R0101 Rev C
E.8 Technical Data
Table E-2. Technical Data for Different Types of Load Cell PFTL 101
PFTL 101 Type Data Unit
Nominal load
Nominal load in measuring direction, F
nom
A/AE/AER 0.5
(112)
1.0
(225)
2.0
(450)
kN
(lbs)
B/BE/BER 2.0
(450)
5.0
(1120)
10.0
(2250)
20.0
(4500)
Permitted transverse load
within the accuracy, F
Vnom
A/AE/AER 5
(1120)
10
(2250)
10
(2250)
B/BE/BER 30
(6740)
30
(6740)
30
(6740)
40
(9000)
Permitted axial load
within the accuracy, F
Anom
A/AE/AER 2
(450)
5
(1120)
5
(1120)
B/BE/BER 5
(1120)
10
(2250)
10
(2250)
10
(2250)
Overload capacity
Max. load in measuring direction without
permanent change of data, F
max
A/AE/AER 2.5
(562)
5
(1120)
10
(2250)
B/BE/BER 10
(2250)
25
(5620)
50
(11200)
80
(18000)
Spring constant
A/AE/AER 32
(183)
65
(372)
130
(744)
kN/mm
(1000
lbs/in.)
B/BE/BER 130
(744)
325
(1860)
650
(3718)
1300
(7440)
Mechanical data
Length
A/AE/AER 230
(9)
230
(9)
230
(9)
mm
(inch)
B/BE/BER 360
(14)
360
(14)
360
(14)
360
(14)
Width
A/AE/AER 84
(3.3)
84
(3.3)
84
(3.3)
B/BE/BER 104
(4)
104
(4)
104
(4)
104
(4)
Height
A/AE/AER 125
(5)
125
(5)
125
(5)
B/BE/BER 125
(5)
125
(5)
125
(5)
125
(5)