8.4 LIST OF ALARMS
Table of contents Meaning Note
AL01 Clock battery faulty or not connected
AL02 Expansion memory damaged
AL03 ID8 phase monitor
AL04 --
AL05 High pressure sensor circuit 1 faulty or not connected U5
AL06 High pressure sensor circuit 2 faulty or not connected U6
AL07 Low pressure sensor circuit 1 faulty or not connected U8
AL08 Low pressure sensor circuit 2 faulty or not connected U9
AL09 Inlet water temp sensor evap.1 faulty or not connected U1
AL10 Outlet water temp sensor evap.1 faulty or not connected U2
AL11 Outlet water temp sensor evap.com. faulty or not connected
AL12 Inlet water temp sensor recovery faulty or not connected
AL13 Outlet water temp sensor recovery1 faulty or not connected
AL14 Outlet water temp sensor recovery2 faulty or not connected
AL15 Outlet water temp sensor recovery common faulty or not connected
AL16 External temperature sensor faulty or not connected U3
AL17 Circuit 1 Liquid temperature probe broken or not connected U4
AL18 Liquid temperature sensor circuit 2 faulty or not connected U7
AL19 Request for maintenance on compressors of circuit 1
AL23 Circuit breaker compressor 1 circuit 1
AL24 Thermal alarm system pump 1 ID 6
AL25 Thermal alarm system pump 2
AL28 Fans circuit breaker circuit 1
AL29 Fans circuit breaker circuit 2
AL30 Low pressure indicated by pressure switch on circuit 1
AL31 Low pressure sensor circuit 1
AL32 High pressure indicated by pressure switch on circuit 1
AL33 High pressure sensor circuit 1
AL34 Circuit 1 Low pressure from probe (not delayed)
AL35 Circuit 2 Low pressure from probe (not delayed)
AL38 Loss of evaporator water ow
AL40 Anti-freeze alarm system inlet/outlet temperature
AL41 Anti-freeze alarm system common outlet temperature
AL42 Antifreeze alarm for recovery inlet/outlet temperature
AL43 Anti-freeze alarm heat recovery 2 outlet temperature
AL45 Expansion IO (uPC) O-line
AL46 Expansion IO (pCOe) O-line
AL48 Discharge gas temperature sensor circuit 1 faulty or not connected
AL49 Discharge gas temperature sensor circuit 2 faulty or not connected
AL50 Board re-start from lost power It is not an alarm
AL59 Circuit breaker compressor 2 circuit 1
AL60 Circuit breaker compressor 3 circuit 1
AL61 Circuit breaker compressor 1 circuit 2
AL62 Circuit breaker compressor 2 circuit 2
AL63 Circuit breaker compressor 3 circuit 2
AL64 Pressure switch BP 2 from pressure switch
AL65 Low pressure 2 from probe
AL66 High pressure pressostat circuit 2
AL67 High pressure sensor circuit 2
AL75 High discharge gas temperature circuit 1
AL76 High discharge gas temperature circuit 2
AL85 High system inlet temperature alarm
AL87 Master Oine
AL88 Slave Oine
AL89 Incorrect Master/Slave software version (the two cards don’t have the same software version)
AL90 Free-cooling output alarm
AL91 Slave alarm summary
AL92 Flow switch Glycol Free
AL93 Glycol Free pump thermal
AL94 PCOE expansion oine (address=3) Unit DK
AL95 Common evaporator output probe broken or not connected (DK)
AL96 Evaporator 2 output probe broken or not connected
AL97 Free-cooling inlet probe faulty or not connected
AL98 Free cooling output probe broken or not connected
AL99 Heat exchanger input probe damaged or not connected
AL100 Oine pCOE expansion (address=4) condenser unit
AL101 Oine pCOE expansion (address=5) NYB Freecooling