3.3.17 Fault code 15.1.00 -
Fault code DIN brief description Cause Consequences Remedy
15 = front axle suspension
0, 1, 2 = fault weighting (0 = heavy, 1 = medium; 2 = light)
01... = sequential number
The sorting of the error code is based on the serial number
15.1.62
Y065 suspension raise solenoid valve
Function non-operable Circuit diagram
15.1.63
Y064 suspension lower solenoid valve
Function non-operable Circuit diagram
15.1.64
A100 MFA, multifunction armrest
Suspension raise button (VA suspension)
Faulty button, signal fault
15.1.65
A100 MFA, multifunction armrest
Suspension lock button, FA suspension
Faulty button, signal fault
15.1.66
Y012 suspension loading/oil preheating solenoid
valve
Function non-operable Circuit diagram
Hydraulics
15.1.67
B066 left wheel position sensor
Sensor faulty,
Signal fault
8.5 V supply A150, fuse 47
15.1.68
B068 right wheel position sensor
Sensor faulty,
Signal fault
Circuit diagram
8.5 V supply A150, fuse 46
15.1.69
Y063 wobble stabilizer solenoid valve
Function non-operable Circuit diagram
15.1.6B
Y067 suspension locking solenoid valve
Solenoid valve faulty,
Actuation fault
Circuit diagram
3. Faults and remedy
212 Maintenance
530.020.020.011 Rev.A

Table of Contents