MMEMory Subsystem
MMEMory:DOWNload:FNAMe <filename>
Creates or opens the specified filename prior to writing data to that file with MMEMory:DOWNload:DATA.
Parameter Typical Return
Any valid file name (none)
Write the word "Hello" to the file "\Myfile" on the internal flash file system:
MMEM:DOWN:FNAM "INT:\Myfile"MMEM:DOWN:DATA #15Hello
MMEMory:LOAD:ALL <filename>
MMEMory:STORe:ALL <filename>
Loads or saves a complete instrument setup, using a named file on the mass storage.
Parameter Typical Return
Any valid file name on current mass storage directory (none)
Store instrument setup to file named "completeSetup.all" on internal storage:
MMEM:STOR:ALL "INT:\completeSetup.all"
Load a complete instrument setup from the file in internal mass memory.
MMEM:LOAD:ALL "INT:\completeSetup.all"
l These commands allow you to duplicate instrument conditions from some previous time.
l This command loads the current instrument setup (such as is used by *SAV and *RCL).
l Instrument setup files used by these commands contain much more than the state files used by *SAV and *RCL.
They also contain stored states and arbitrary waveforms, GPIB and LAN parameters, number format, beep on/off,
display options, and help language.
l If the destination file exists, it is overwritten, unless marked as hidden or system.
MMEMory:LOAD:DATA[1|2] <filename>
Loads the specified arb segment(.arb/.barb) or arb sequence (.seq) file in INTERNAL or USB memory into volatile mem-
ory for the specified channel.
Parameter Typical Return
Any valid file name, as described below. (none)
Load an arbitrary waveform segment from the internal drive into volatile memory for channel 1 and selects it for
use.
MMEM:LOAD:DATA "Int:\Builtin\HAVERSINE.arb"
FUNC:ARB "Int:\Builtin\HAVERSINE.ARB"
256 Agilent 33500 Series Operating and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies Agilent 33500 Series and is the answer not in the manual?

Agilent Technologies Agilent 33500 Series Specifications

General IconGeneral
BrandAgilent Technologies
ModelAgilent 33500 Series
CategoryInverter
LanguageEnglish

Related product manuals