271
Hardware Reference Manual – Enova DGX 100 Series Digital Media Switchers
2. Apply power to the enclosure.
3. On the PC, open DGX Configuration Software.
4. From the Communication menu:
a. Select Serial Port.
b. Select Change Settings, change the Baud Rate to 115200, and click OK.
5. From the Terminal tab:
a. Change the Baud Rate to 115200 and click Connect.
b. In the Command field, enter: CTRL+C, then type bcs and click the Send button.
c. Click Disconnect.
6. From the Communication menu, select Refresh Device.
General Notes for Working with DGX Configuration Software
DGX Configuration Software only displays inputs and/or outputs that can be modified.
File menu – Select Open File to load a file to the program (the file type available depends on the selected view). Select Save
to File to save a file containing the currently displayed settings in the currently selected view.
Communication menu – Use to change the communication settings for the DB-9 serial and Ethernet ports. This menu also
includes the option to “Refresh Device Lists,” which affects all device lists in the program.
Utilities menu – If the program cannot read and write the EDID data from the destination devices, the system may not
support all of the DGX Configuration Software functionality.
Help menu – Access the Help file for the program, open a link for the Web Update option (to download updates for the
program), and view current version information.
Messages in the bottom pane of the DGX Configuration Software dialog box report status of operations. Messages can be
copied* for technical support purposes.
DXLink Fiber hardware – Only Duplex hardware in Bidirectional Mode with both fibers connected will allow DGX
Configuration Software to read EDID data from a destination device.
* Right-click on a message to access a short-cut menu with options to Copy Selected, Copy All, or Clear. When copying multiple
messages: either select consecutive items by holding down the Shift key and clicking the first and last item or select
nonconsecutive items by holding down the Control key and clicking on each item.
Communication menu
Terminal tab
Connect/Disconnect
button
Change Settings
dialog box
Send button

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AMX DGX800-ENC and is the answer not in the manual?

AMX DGX800-ENC Specifications

General IconGeneral
BrandAMX
ModelDGX800-ENC
CategorySwitch
LanguageEnglish

Related product manuals