OSCi service kit
1 Oleophilic filter
2 Buckets (can be used to receive the used filters after maintenance)
3 OGC filter
4 Gloves
5 Activated carbon filter
part number Filter kit OSCi: 2901 1734 00
5.10 Problem solving
Condition Fault Remedy
A lot of oil entered the
OSCi.
Compressor
malfunctioning
Replace all filters. Clean the vessels. Check the compressor.
The Elektronikon®
controller shows
overflow warning, or
visible overflow (sight-
glass).
A section of the outlet
tube is higher than the
corresponding outlet
connection.
Reposition the outlet tube to below the outlet connection level
(View of OSCi outlet) (check inside and outside the
compressor).
A filter is saturated. Replace filters and clean the OSCi
Injected air flow too
high
Replace strainer (4-OSCi air injection).
Instruction book
2920 7109 60 135