3.23 Calling up/modifying unit of pressure
Control panel
Starting from the Main screen:
• Press Scroll button (12) until <P.08> and the possible settings are shown (<Mpa>, <psi>, and <bar>).
Press Enter button (13) and the actually used unit is shown.
• Press Enter button (13) (unit starts blinking) and use the Scroll buttons (12) to select another unit of
pressure.
• Press Enter button (13) to program the new unit of pressure. Press the escape button (14) to return to the
parameter screens.
3.24 Activating automatic restart after voltage failure
Description
This function allows the compressor to restart automatically after a power failure.
This parameter, accessible in screen <P. 9>, can only be modified after entering a code. Consult your supplier
if this function is to be activated.
3.25 Selection between Y-D or DOL starting
Control panel
Starting from the Main screen:
• Press Scroll button (12) until <P.10> and the motor pictograph is shown and then press Enter button (13).
The actually used starting mode is shown: <Y-D> (star-delta) or <doL> (Direct-On Line).