Transport and storage 25/60
RE 92801-01-B/11.2018, A15VSO/A15VLO Series 11, BoschRexrothAG
An uninstalled axial piston unit must bepreserved with corrosion protection for the
duration ofstorage.
The following instructions only refer toaxial piston units operated with hydraulic
fluid on amineral oil basis. Other hydraulic fluids require other specific
preservation measures. In such acase, consult your local contact person; you can
find their contact information at
www.boschrexroth.com/addresses
BoschRexroth recommends the following procedure:
1. Clean the axial piston unit; seechapter10.1 "Cleaning and care" onpage47.
2. Drain the axial piston unit.
3. For storage times up to12 months: Moisten the inside oftheaxial piston unit
with mineral oil and fill with approx. 100 ml mineral oil.
For storage times up to24months: Fill the axial piston unit with VCI329
corrosion protection (20ml).
The filling iscarried out via the drain port T
1
, T
2
orT
3
, seechapter7.4 "Installing
the axial piston unit", Fig. 14 toFig. 16 onpage38.
4. Plug all ports sothey are airproof.
5. Coat unpainted areas oftheaxial piston unit with mineral oil orsuitable, easily
removable corrosion protection, e.g.acid-free grease.
6. Package the axial piston unit with desiccant incorrosion protection film soit
isairproof.
7. Store the axial piston unit inashock-proof manner; see "Requirement"
onpage24 inthis chapter.