Commissioning 43/60
RE 92801-01-B/11.2018, A15VSO/A15VLO Series 11, BoschRexrothAG
8 Commissioning
WARNING
Danger while working inthe danger zone ofamachine/system!
Danger tolife, risk ofinjury orserious injury!
▶ Pay attention toand eliminate potential danger sources before commissioning
the axial piston unit.
▶ Make sure noone isinthe danger zone ofthemachine/system.
▶ The emergency stop button for the machine/system should bewithin the
operator's reach.
▶ Always follow the instructions ofthemachine/system manufacturer during
commissioning.
CAUTION
Commissioning animproperly installed product!
Risk ofinjury and property damage!
▶ Make sure all electrical and hydraulic ports are connected orplugged.
▶ Commission only afully installed, fully functioning product with original
accessories from BoschRexroth.
8.1 Initial commissioning
During all commissioning work onthe axial piston unit, observe the general safety
instructions and intended use detailed inchapter2 "Safety instructions"
onpage8.
▶ Connect the pressure gage for the working pressure, case pressure and suction
pressure tothe specified measuring points onthe axial piston unit orinthe
hydraulic system, tocheck the technical data atfirst operation.
▶ During commissioning, monitor the temperature ofthehydraulic fluid inthe
reservoir toensure that itlies within permissible viscosity limits.
8.1.1 Filling the axial piston unit
Professional filling and air bleeding isnecessary toprevent damage tothe axial
piston unit and tomaintain proper function.
Usually, the cleanliness level ofcommercial hydraulic fluids isinsufficient for our
components. These hydraulic fluids must befiltered using anappropriate filter
system tominimize solid particle contamination and water inthe system.