Installation 35/60
RE 92801-01-B/11.2018, A15VSO/A15VLO Series 11, BoschRexrothAG
5
3
4
4
1
2
or
X (LRDRS0)
Fig. 13: Removing transport protection
1 Protective cover
2 Threaded plugs
3 Protective plug
4 Steel flange covers (the flange cover
onthe suction port provides asecure
stand and protection for the V
g max
stop)
5 For version with through drive,
protective cover and mounting
bolts
Ports intended for connecting lines come with protective plugs orthreaded plugs,
which serve astransport protection. Connect all ports required for functional
operation (see Table 12 "Ports A15VSO/A15VLO series 11" onpage39). Failure
todo socould lead tomalfunctions ordamage. If aport isnot being used, it is to
bepluggedwith athreaded plug since the protective plugs are not pressure-resistant.
Important for LRDRS0 controllers! Port X isequipped with aprotective plug (3).
This port must beconnected. Failure todo socould lead tomalfunctions
ordamage.
You will find other ports for the respective control inthe datasheet92801.
Setting screws are protected against unauthorized adjustment bytamper-proof
caps. Removal ofthetamper-proof caps will void the warranty. If you need
tochange the settings, please contact your local contact person; you can find
their contact information at
www.boschrexroth.com/addresses