Page #40 background imageLoading...
Page #40 background image
40/60 Installation
Bosch Rexroth AG, A15VSO/A15VLO Series 11, RE 92801-01-B/11.2018
Table 13: Tightening torques for female threads and threaded plugs
Ports
Maximum permissible
tightening torque offemale
threads M
Gmax
Required tightening torque
ofthreaded plugs M
V
WAF hexagon socket
ofthethreaded plug
Standard Thread size
ISO6149 M8×1 10Nm 7Nm 4mm
M10×1 30Nm 15Nm 5mm
M12×1.5 50Nm 25Nm 6mm
M14×1.5 80Nm 45Nm 6mm
M16×1.5 100Nm 55Nm 8mm
M18×1.5 140 Nm 70Nm 8mm
M20×1.5 170Nm 80Nm 10mm
M22×1.5 210Nm 100Nm 10mm
M27×2 330Nm 170Nm 12mm
M30×2 420Nm 215 Nm 17mm
M33×2 540Nm 310Nm 17mm
M42×2 720Nm 330Nm 22mm
M48×2 900Nm 420Nm 22mm
1)
The tightening torques for the threaded plugs are valid for the condition "dry" and "lightly oiled".
2)
The tightening torques for the threaded plugs are valid for the condition "dry" – inthe condition "lightly oiled", the tightening torques
for M10×1 are reduced to10Nm and for M12×1.5 to17Nm.
To connect the axial piston unit tothe hydraulic system:
1. Remove the protective plugs orthreaded plugs from the ports where the
connections should bemade according tothe hydraulic circuit diagram.
2. Make sure the sealing surfaces ofthehydraulic ports and functional surfaces are
not damaged.
3. Use only clean hydraulic lines orflush them before installation.
(Observechapter7.5 "Performing flushing cycle" onpage42 when you flush
out the entire system.)
4. Connect the lines inaccordance with the installation drawing and the machine
orsystem circuit diagram. Check that all ports are connected orplugged with
threaded plugs. With inside-reservoir installation, the housing oftheaxial
piston unit must befilled before fitting the lines and filling the reservoir with
hydraulicfluid.
5. Properly tighten the fittings (observe tightening torques!). Mark all properly
tightened fittings, e.g.with apermanent marker.
6. Check all pipes and hose lines and every combination ofconnecting pieces,
couplings orconnecting points with hoses orpipes toensure they are insafe
working condition.
Procedure

Table of Contents