Item Option
Zone Options 1 1 = Lockout siren/report
2 = Delay alarm report
4 = Silent alarm
8 = Sensor watch
Zone Options 2 1 = Isolated in STAY Mode 1
2 = Zone isolation allowed
4 = Forced arming allowed
8 = Zone Restore Report allowed
Zone Report Options 0 = No zone reports allowed
1 = Report to Receiver 1
2 = Report to Receiver 2
4 = Report to both Receiver 1 and Receiver 2
8 = Report to Receiver 2 only if Receiver 1 fails
Keyswitch Zone Options 0 = Latching arm and disarm in AWAY Mode
1 = Latching arm in AWAY Mode
2 = Latching disarm from AWAY Mode or STAY Mode
4 = Latching arm and disarm in STAY Mode 1
5 = Latching arm in STAY Mode 1
6 = Latching disarm from STAY Mode
8 = Momentary arm and disarm in AWAY Mode
9 = Momentary arm in AWAY Mode
10 = Momentary disarm from AWAY Mode or STAY Mode
12 = Momentary arm and disarm in STAY Mode 1
13 = Momentary arm in STAY Mode 1
14 = Momentary disarm from STAY Mode
Table 4.3: Zone Item Options
The keyswitch zone options replace Zone Options 1 only for the zones that were programmed
to operate as a keyswitch zone.
Notice!
Solution 2000 supports zone 1 – 8 only.
Swinger Programming
Swinger Shutdown Count For Siren
Item Location Option Default New
Swinger Shutdown Count
For Siren
0379 1 – 15 = Number of times siren operates
until lockout
3
4.7
4.7.1
30 en | Programming Parameters Control Panel
2015.06 | 03 | F.01U.298.027 Quick Reference Guide Bosch Security Systems, Inc.