Page #31 background imageLoading...
Page #31 background image
Swinger Shutdown Count For Report
Item Location Option Default New
Swinger Shutdown Count
For Report
0380 1 – 15 = Number of times report operates
until lockout
6
Zone Status Programming
STAY Mode 2 Automatically Bypass Zones
Item Location Option Default New
STAY Mode 2
Automatically Bypass
Zones
0381 1 = Zone 1
2 = Zone 2
4 = Zone 3
8 = Zone 4
0
0382 1 = Zone 5
2 = Zone 6
4 = Zone 7
8 = Zone 8
0
0383 1 = Zone 9
2 = Zone 10
4 = Zone 11
8 = Zone 12
0
0384 1 = Zone 13
2 = Zone 14
4 = Zone 15
8 = Zone 16
0
Notice!
Solution 2000 supports zone 1 – 8 only.
Zone Status Reporting Options
Item Location Option Default New
Zone Status Reporting
Options
0392 0 = No Zone status reports allowed
1 = Report to Receiver 1
2 = Report to Receiver 2
4 = Report to both Receiver 1 and Receiver 2
8 = Report to Receiver 2 only Receiver 1 fails
1
RF Programming
RF Supervision Time
Item Location Option Default New
RF Supervision Time
(Only for Solution
3000 )
0393 0 = Disable
2 = 2 hours
3 = 4 hours
4 = 12 hours
5 = 24 hours
6 = 48 hours
7 = 72 hours
0
4.7.2
4.8
4.8.1
4.8.2
4.9
4.9.1
Control Panel Programming Parameters | en 31
Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027

Table of Contents

Other manuals for Bosch Solution 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 2000 and is the answer not in the manual?

Bosch Solution 2000 Specifications

General IconGeneral
BrandBosch
ModelSolution 2000
CategoryControl Panel
LanguageEnglish

Related product manuals