8200-M129-O1 Rev D 205 Installation & Technical 1
SPECIFICATIONS
Power Requirements: 100 to 240 VAC (50/60 Hz) at 0.4A Max.
Enclosure Type: Stainless Steel wall or desk-mount
Enclosure Size:
9 3/16" W x 7 1/2" H x 3 1/8" D
(233 mm W x 191 mm H x 79 mm D)
Weight: 8.2 lb (3.7 kg)
Operating Environment:
Compensated Temperature Range: 14º to 104º F (-10º to +40º C)
Operated Temperature Range: -10º to 122º F (-23º to +50º C)
Humidity: 0 to 90% non-condensing
Display:
Six digit, seven segment, 0.6" (15 mm) high LED
Transducer Excitation: 9.4 VDC
Signal Input Range: 1.0 mV min. to 31 mV max. (with dead load boost)
Number of Load Cells: 8 each, 350-ohm load cells
Load Cell Cable Length:
1,500 feet maximum (requires the use of sense lines). Consult
factory for other requirements
30 feet maximum without sense lines
Division Value:
Commercial: 1, 2, or 5 x 10, 1, 0.1, 0.01, 0.001
Non-commercial: 1 to 99 x 10, 1, 0.1, 0.01, 0.001.
Sensitivity:
NON-COMMERCIAL
NTEP
CANADA
OIML
0.15 uV/e
0.3uV/e (Class III/IIIL)
0.3uV/e (Class III/IIIHD)
0.5 uV/e (Class III)
Scale Divisions:
NON-COMMERCIAL
NTEP
CANADA
OIML
100 to 240,000
500 to 10,000 (Class III/IIIL)
500 to 10,000 (Class III/IIIHD)
500 to 10,000 (Class III)
Internal Resolution: 1 part in 16,777,216
Tare Capacity: Scale Capacity
Sample Rate: 1 to 100 samples per second, selectable
Auto Zero Range: 0.5 or 1 through 9 divisions
Weighing Units:
Tons, Pounds, Pounds-Ounces, Ounces, Metric Tons, Kilograms,
and Grams
Keypad: Color coded Membrane type, 7 keys
Standard I/O:
4 ea Serial I/O Ports configured as:
4 ea bi-directional RS-232 ports
1 ea 20mA output-only ports (uses one of the four RS-232 ports)
1 ea bi-directional 20mA port (uses one of the four RS-232 ports)
1 ea USB port (uses one of the four RS-232 ports)