EasyManuals Logo
Home>Carlyle>Air Compressor>06CC

Carlyle 06CC User Manual

Default Icon
167 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
3
1.0 — GENERAL COMPRESSOR AND CUSTOMER
INFORMATION
1.1 — Compressor Model Number Significance
}
}
06D COMPRESSORS
06DR 3 37 0 D A 36 5 A – (RP)**
Model = 0, Package = 1 or 9, A = Shipped Without Oil
Oil and Refrigeration (06DR, DM) Unloading Variable:
0 = All Models Except as Noted
5 = No Oil
7 = 1 Unloader Elec. (DR, DM Only)
8 = 2 Unloaders
Electrical Characteristics (XL Start Only, Unless Noted):
New H.E. Models Old Std. Models
31 = 575-3-60 01 = 575-3-60 12 = 208/230-3-60
32 = 208/230-3-60 04 = 200-3-60 13 = 380-3-60
33 = 208/230-1-60 05 = 230-3-60 14 = 200-3-60 (PW)
34 = 220-3-50 06 = 400/460-3-50/60 15 = 230-3-60 (PW)
36 = 400/460-3-50/60 08 = 220-3-50 18 = 220-3-50 (PW)
Electrical Variables:
A = With Internal Thermostat and External Overloads
C = With Internal Thermostat and Without External Overloads
Suction Valve - Variables:
Location, Orientation and Mounting Bolts
Compressor Identification Key:
0 = New Compressor
2 = New Compressor
3 = New Compressor
6 = Service Compressor, Remanufactured
7 = Service Compressor, New Manufactured
8 = New Compressor, Special
9 = Service Compressor, Special
Displacement (in Cfm at 1750 rpm)
Motor Size - (Does Not Signify Horsepower)
Compressor Type:
06DA = Compressor - A/C Duty No Unloading
06DB = Compressor - A/C Duty 1-Step Elec.
06DC = Compressor - A/C Duty 2-Step Elec.
06DD = Compressor - A/C Duty 1-Step Press.
06DE = Compressor - A/C Duty 2-Step Press.
06DF = Compressor - A/C Duty 1-Step Elec.
06DG = Compressor - A/C Duty 2-Step Elec.
06DH = Compressor - A/C Duty 1-Step Press.
06DJ = Compressor - A/C Duty 2-Step Press.
06DM = Compressor Refrig. Duty Medium Temperature
06DR = Compressor Refrig. Duty Low Temperature
06DM = Service Compressor-Replacement for new 06DA, DM without unloading
06DS = Service Compressor-Replacement for new 06DF,G,H and J with
suction cut-off unloading. Compressor has 1-Stage suction
cut-off unloading
06DX = Service Compressor-Replacement for new 06DB,C,D, and E with
hot gas (bypass) unloading. Compressor has 1-stage of bypass unloading
**Refrigeration Partner.
Information in shaded area is no longer available in standard factory production.
Hot Gas
Bypass
Unloading
Suction
Cut-Off
Unloading
Y = Smart Unloading Models
S = Oil Sensor Block and OPSS Sensor
06DK = Compressor - A/C Duty 1-Step Elec. & 2-Step Press.
Suction Cut-Off Unloading Designation for 06DR, DM Compressors:
37 = 380-3-60
Electronic Overcurrent Protection:
0 = None
1 = 115/240V Control Voltage, Electronic Overcurrent Protection
2 = 24V AC Control Voltage, Electronic Overcurrent Protection
3 = 24V DC Control Voltage, Electronic Overcurrent Protection
Electromechanical Overcurrent Protection:

Table of Contents

Other manuals for Carlyle 06CC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carlyle 06CC and is the answer not in the manual?

Carlyle 06CC Specifications

General IconGeneral
BrandCarlyle
Model06CC
CategoryAir Compressor
LanguageEnglish

Related product manuals