3-64
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
E
“INCORRECT START“ MANAGEMENT
The “INCORRECT START“ are recoverable errors, generated by:
• an incorrect starting procedure
• an incorrect sequence of use of the controls
These alarms block truck functioning temporarily, generating an alarm icon on the display.
Summary table of the “INCORRECT START“
Icon Description
Configuration. Notes
Direction pedal pressed during the start-
ing procedure
Double pedal system
or balanced pedal
system
Traction: NO
Lifting: YES:
Manual inversor in direction position
Pedal system
single
Traction: NO
Lifting: YES:
Hydraulic request during the starting pro-
cedure
BOARD
microswitch
Traction: NO
Lifting: NO
Hydraulic request during the starting pro-
cedure
Electric distributor
Traction: NO
Lifting: NO
Double drive request signal
Double pedal system
or balanced pedal
system
Traction: NO
Lifting: YES:
Direction request with
parking brake on
All
Traction: NO
Lifting: NO
Seat micro opened during movement or
hydraulic request
All
Traction: NO
Lifting: NO
Brakes liquid level warning light:
the brakes liquid is going to finish; the
The signal is shown when the brakes oil
level is too low.
In case of alarm the truck reduces the
maximum speed to about 5Km/ h
All
Traction: YES:
Lifting: YES:
https://www.forkliftpdfmanuals.com/