Page #38 background image
1-8
BDI ADJ MAX
The parameter BDI ADJ MIN determines the voltage above which the battery indicator signals 100%
charge.
Parameter Min value Max value Step Standard Notes
BDI ADJ MAX - 12,80% + 12,70% 0,10% - 3,00%
0,00% = 25,320 V
± 0,10% = ± 0,024 V
± 1,00% = ± 0,240 V
STD
Low voltage at charge end
High voltage at charge end