Page #13 background image
Modular RAID (mRAID) riser, can optionally be a
riser that supports either:
Hardware RAID controller card
Interposer card for embedded SATA RAID
15Mini-storage module socket. Options:
SD card module with two SD card slots
M.2 module with slots for either two SATA
M.2 drives or two NVMe M.2 drives
Cisco Boot-Optimized M.2 RAID Controller
(module with two slots for SATA M.2 drives,
plus an integrated SATA RAID controller that
can control the two M.2 drives in a RAID 1
array)
6
PCIe cable connectors for front-loading NVMe SSDs
on PCIe riser 2
16Chassis intrusion switch (optional)7
Micro-SD card socket on PCIe riser 117Internal USB 3.0 port on motherboard8
-RTC battery, vertical socket9
The Technical Specifications Sheets for all versions of this server, which include supported component part
numbers, are at Cisco UCS Servers Technical Specifications Sheets (scroll down to Technical Specifications).
Replacing SAS/SATA Hard Drives or Solid State Drives
You do not have to shut down the server or drive to replace SAS/SATA hard drives or SSDs because they
are hot-swappable. To replace an NVMe PCIe SSD drive, which must be shut down before removal, see
Replacing a Front-Loading NVMe SSD, on page 16.
Note
SAS/SATA Drive Population Guidelines
The server is orderable in three different versions, each with a different front panel/drive-backplane
configuration.
Cisco UCS C220 M5 (UCSC-220-M5SX)—Small form-factor (SFF) drives, with 10-drive backplane.
Supports up to 10 2.5-inch SAS/SATA drives. Drive bays 1 and 2 support NVMe SSDs.
Cisco UCS C220 M5 (UCSC-220-M5SN)—SFF drives, with 10-drive backplane. Supports up to 10
2.5-inch NVMe-only SSDs.
Cisco UCS C220 M5 (UCSC-220-M5L)—Large form-factor (LFF) drives, with four-drive backplane.
Supports up to four 3.5-inch SAS/SATA drives. Drive bays 1 and 2 support NVMe SSDs. A size-converter
drive sled is required to hold 2.5-inch SSDs.
Drive bay numbering is shown in the following figures.
Maintaining the Server
13
Maintaining the Server
Replacing SAS/SATA Hard Drives or Solid State Drives

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco UCS C220 M5 and is the answer not in the manual?

Cisco UCS C220 M5 Specifications

General IconGeneral
Processor cache22 MB
Processor model6130
Execute Disable BitYes
Processor frequency2.1 GHz
Processor manufacturerIntel
Processor boost frequency3.7 GHz
Number of processors installed2
On-board graphics card-
Memory slots24
Internal memory64 GB
Internal memory typeDDR4-SDRAM
Maximum internal memory128 GB
SSD interfaceSerial Attached SCSI (SAS)
Optical drive typeNo
Supported HDD sizes2.5, 3.5 \
Supported SSD sizes2.5\
Total storage capacity32 GB
Maximum storage capacity- TB
Chassis typeRack (1U)
Power supply700 W
Intel TSX-NI version1.00