Figure 9: Replacing a Drive in a Drive Tray
Drive tray screws (two on each side)3Ejector lever1
Drive removed from drive tray4Release button2
Installing a PCIe Cable For Front-Loading NVMe SSDs
The front-loading NVMe SSDs interface with the server via the PCIe bus. Cable CBL-NVME-C220FF
connects the front-panel drive backplane to the PCIe riser 2 board on the PCIe riser assembly.
If the server was ordered with 2.5- or 3.5-inch form-factor NVMe SSDs, this cable was preinstalled at
the factory. No action is required.
If you are adding 2.5- or 3.5-inch form-factor NVMe SSDs for the first time, you must order and install
the cable as described in the following procedure.
Maintaining the Server
19
Maintaining the Server
Installing a PCIe Cable For Front-Loading NVMe SSDs

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco UCS C220 M5 and is the answer not in the manual?

Cisco UCS C220 M5 Specifications

General IconGeneral
Processor cache22 MB
Processor model6130
Execute Disable BitYes
Processor frequency2.1 GHz
Processor manufacturerIntel
Processor boost frequency3.7 GHz
Number of processors installed2
On-board graphics card-
Memory slots24
Internal memory64 GB
Internal memory typeDDR4-SDRAM
Maximum internal memory128 GB
SSD interfaceSerial Attached SCSI (SAS)
Optical drive typeNo
Supported HDD sizes2.5, 3.5 \
Supported SSD sizes2.5\
Total storage capacity32 GB
Maximum storage capacity- TB
Chassis typeRack (1U)
Power supply700 W
Intel TSX-NI version1.00