A readily accessible two-poled disconnect device must be incorporated in the fixed wiring.
Statement 1022
Warning
This product requires short-circuit (overcurrent) protection, to be provided as part of the building
installation. Install only in accordance with national and local wiring regulations.
Statement 1045
Warning
Installation of the equipment must comply with local and national electrical codes.
Statement 1074
Warning
If you are replacing DC power supplies in a server with power supply redundancy (two power supplies), you
do not have to power off the server to replace a power supply because they are redundant as 1+1.
Note
Do not mix power supply types or wattages in the server. Both power supplies must be identical.
Note
Step 1 Remove the DC power supply that you are replacing or a blank panel from an empty bay:
a) Perform one of the following actions:
If you are replacing a power supply in a server that has only one DC power supply, shut down and remove power
from the server as described in Shutting Down and Removing Power From the Server, on page 7.
If you are replacing a power supply in a server that has two DC power supplies, you do not have to shut down
the server.
b) Remove the power cord from the power supply that you are replacing. Lift the connector securing clip slightly and
then pull the connector from the socket on the power supply.
c) Grasp the power supply handle while pinching the release lever toward the handle.
d) Pull the power supply out of the bay.
Step 2 Install a new DC power supply:
a) Grasp the power supply handle and insert the new power supply into the empty bay.
b) Push the power supply into the bay until the release lever locks.
c) Connect the power cord to the new power supply. Press the connector into the socket until the securing clip clicks
into place.
d) Only if you shut down the server, press the Power button to boot the server to main power mode.
Maintaining the Server
53
Maintaining the Server
Replacing DC Power Supplies

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco UCS C220 M5 and is the answer not in the manual?

Cisco UCS C220 M5 Specifications

General IconGeneral
Processor cache22 MB
Processor model6130
Execute Disable BitYes
Processor frequency2.1 GHz
Processor manufacturerIntel
Processor boost frequency3.7 GHz
Number of processors installed2
On-board graphics card-
Memory slots24
Internal memory64 GB
Internal memory typeDDR4-SDRAM
Maximum internal memory128 GB
SSD interfaceSerial Attached SCSI (SAS)
Optical drive typeNo
Supported HDD sizes2.5, 3.5 \
Supported SSD sizes2.5\
Total storage capacity32 GB
Maximum storage capacity- TB
Chassis typeRack (1U)
Power supply700 W
Intel TSX-NI version1.00