8
Specifications
FSM3
Series
*1: The value converted to volumetric ow rate at standard condition (20°C 1 barometric pressure (101 kPa) relative humidity 65%)
*2: Use dry gas which does not contain corrosive elements such as chlorine, sulfur or acids, and which is clean and does not contain dust or
oil mist. When using compressed air, use clean air that complies with JIS B 8392-1:2012 Class 1.1.1 to 1.6.2. Compressed air from the
compressor contains drain (water, oil oxide, foreign substances, etc.) To maintain the function of this product, install a lter, air dryer (min.
pressure dew point 10°C or less), and oil mist lter (max. oil content 0.1 mg/m
3
) on the primary side (upstream side) of this product. (Refer
to the recommended values on page 42.)
*3: The accuracy is based on CKD's basic ow rate meter. It does not show absolute accuracy.
*4: Repeatability over a short period of time. Change over time is not included. (Refer to the product specications sheet for details.)
*5: Actual response time may differ depending on piping conditions.
*6: The output impedance of the analog output section is approx. 1 kΩ. If the impedance of the connecting load is small, output and error
increase. Check error with the impedance of the connecting load before using.
*7: The power supply voltage specications differ for the voltage output and current output.
*8: Current for when 24 VDC is connected and no load is applied. The current consumption will vary depending on how the load is connected.
*9: This product's protection circuit is effective only for specic misconnections and load short-circuits. It does not provide protection for all
misconnections.
*10: This product measures the change in heat distribution caused by ow.
When set to horizontal direction, the convection ow can inuence a change in heat distribution, causing the zero point to shift.
*11: Piping conditions may affect accuracy. For more accurate measurements, use a straight pipe with an internal diameter ten times greater.
With the 500 L/min and 1,000 L/min models, use piping with an internal diameter of 9 mm or more. If it is less than 9 mm, accuracy may
be negatively affected.
*12: Refer to page 32 for weight.
LCD display Bar display
IO
-
Link
Internal
structure
Separate
display
Technical
data
Operating
method
Optional
products
Safety
precautions
Related
products

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CKD RAPIFLOW FSM3 Series and is the answer not in the manual?

CKD RAPIFLOW FSM3 Series Specifications

General IconGeneral
BrandCKD
ModelRAPIFLOW FSM3 Series
CategoryAccessories
LanguageEnglish

Related product manuals