3.12 Parameters: 10-** DeviceNet CAN
Fieldbus
3.12.1 10-0* Common Settings
10-00 CAN Protocol
Option: Function:
[0] CANopen
[1]
*
DeviceNet View the active CAN protocol.
NOTE!
The options depend on installed option.
10-01 Baud Rate Select
Select the serial communication bus transmission speed. The
selection must correspond to the transmission speed of the master
and the other serial communication bus nodes.
Option: Function:
[16] 10 Kbps
[17] 20 Kbps
[18] 50 Kbps
[19] 100 Kbps
[20]
*
125 Kbps
[21] 250 Kbps
[22] 500 Kbps
10-02 MAC ID
Range: Function:
Application
dependent
*
[Application
dependant]
Selection of station address.
Every station connected to the
same network must have an
unambiguous address.
10-05 Readout Transmit Error Counter
Range: Function:
0 N/A
*
[0 - 255 N/A] View the number of CAN control
transmission errors since the last power-
up.
10-06 Readout Receive Error Counter
Range: Function:
0 N/A
*
[0 - 255 N/A] View the number of CAN control receipt
errors since the last power-up.
10-07 Readout Bus Off Counter
Range: Function:
0
*
[0 - 255 ] View the number of Bus Off events since the last
power-up.
3.12.2 10-1* DeviceNet
Parameters specific to the DeviceNet serial communication
bus.
10-10 Process Data Type Selection
Option: Function:
Select the Instance (message) for data
transmission. The instances available are
dependent upon the setting of 8-10 Control
Profile.
When 8-10 Control Profile is set to [0] FC
profile, 10-10 Process Data Type Selection
options [0] and [1] are available.
When 8-10 Control Profile is set to [5] ODVA,
10-10 Process Data Type Selection options [2]
and [3] are available.
Instances 100/150 and 101/151 are Danfoss-
specific. Instances 20/70 and 21/71 are ODVA-
specific AC Drive profiles.
For guidelines in message selection, please
refer to the DeviceNet Instruction Manual.
Note that a change to this parameter will be
executed immediately.
[0]
*
INSTANCE
100/150
[1] INSTANCE
101/151
[2] INSTANCE
20/70
[3] INSTANCE
21/71
10-11 Process Data Config Write
Select the process write data for I/O assembly instances 101/151.
Elements [2] and [3] of this array can be selected. Elements [0] and
[1] of the array are fixed.
Option: Function:
[0] None
[302] Minimum Reference
[303] Maximum Reference
[312] Catch up/slow-down Value
[341] Ramp 1 Ramp-up Time
[342] Ramp 1 Ramp-down Time
[351] Ramp 2 Ramp-up Time
[352] Ramp 2 Ramp-down Time
[380] Jog Ramp Time
[381] Quick Stop Ramp Time
[411] Motor Speed Low Limit [RPM]
[412] Motor Speed Low Limit [Hz]
[413] Motor Speed High Limit [RPM]
[414] Motor Speed High Limit [Hz]
[416] Torque Limit Motor Mode
Parameter Descriptions FC 300 Programming Guide
3-98 MG.33.MA.22 - VLT
®
is a registered Danfoss trademark
3
3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss FC 300 Series and is the answer not in the manual?

Danfoss FC 300 Series Specifications

General IconGeneral
BrandDanfoss
ModelFC 300 Series
CategoryDC Drives
LanguageEnglish

Related product manuals