4 Parameter Lists
FC Series
All = valid for FC 301 and FC 302 series
01 = valid for FC 301 only
02 = valid for FC 302 only
Changes during operation
”TRUE” means that the parameter can be changed while the
adjustable frequency drive is in operation, and “FALSE”
means that the adjustable frequency drive must be stopped
before a change can be made.
4-Set-up
'All set-ups': the parameter can be set individually in each of
the four set-ups, i.e., one single parameter can have four
different data values.
’1 set-up’: the data value will be the same in all set-ups.
Conversion index
This number refers to a conversion figure used when writing
or reading by means of an adjustable frequency drive.
Conv. index 100 67 6 5 4 3 2 1 0 -1 -2 -3 -4 -5 -6
Conv. factor 1 1/60 1000000 100000 10000 1000 100 10 1 0.1 0.01 0.001 0.0001 0.00001 0.000001
Data type Description Type
2 Integer 8 Int8
3 Integer 16 Int16
4 Integer 32 Int32
5 Unsigned 8 Uint8
6 Unsigned 16 Uint16
7 Unsigned 32 Uint32
9 Visible String VisStr
33 Normalized value 2 bytes N2
35 Bit sequence of 16 Boolean variables V2
54 Time difference w/o date TimD
Parameter Lists FC 300 Programming Guide
MG.33.MA.22 - VLT
®
is a registered Danfoss trademark 4-1
4