VLT
®
5000 SyncPos option
MG.10.J4.02 – VLT is a registered Danfoss trade mark
12
Terminal A2 A2 B2 B2 Z2 Z2
Incremental input A in A in B in B in Z in Z in
Absolute input Clk out Clk out Data in Data in Not used Not used
Fig. 2
Supply voltages:
The option card is supplied by the internal 24 V
DC supply of VLT 5000, but as the available power
is limited it can be necessary to use an external
24 V DC supply.
The 24 V DC supply of VLT 5000 can supply a total
of 420 mA including the load on the control card
(terminal 12, 13 and output 42 and 45).
The 5 V output on the option card is generated
from the 24 V supply. The maximum power on the
5 V side is 5 V * 280 mA = 1.4 W, this corresponds
to app. 60 mA on the 24 V side.
When an external 24 V DC voltage source is used
the internal 24 V supply from the control card must
be disconnected, this is done by opening
switch 1.1 and 1.5.
Each digital input on the option card takes 8 mA.
Each digital output on the option card can supply
up to 0.7 A (external 24V-supply) depending on the
load.
The load from the 24 V supply (internal or external)
can be calculated as follows:
8 mA * number of digital inputs
+
Load on digital outputs
(mk3 C, O1 – O8)
+
load on 5 V supply
(mk3 B/D, 5 V/com)
+
Load on control card
(24 V supply, terminal 12/13 and
outputs, terminal 42/45)
Input/Output terminals

Table of Contents

Other manuals for Danfoss VLT 5000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 5000 Series and is the answer not in the manual?

Danfoss VLT 5000 Series Specifications

General IconGeneral
BrandDanfoss
ModelVLT 5000 Series
CategoryDC Drives
LanguageEnglish

Related product manuals