VLT
®
5000 SyncPos option
MG.10.J4.02 – VLT is a registered Danfoss trade mark
126
Parameter Reference
Only available if
a field bus option
is installed (see
field bus option
manual).
0..
1..
2..
3..
4..
5..
6..
7..
8..
9..
VLT par. # Option parameter Parameter Read/Write
LCP access # and name Application program
700 — GETVLT/SETVLT parameter number
Ex.: var = GETVLT 700
701 102 PRGPAR
702 11 KPROP
703 12 KDER
704 13 KINT GET/SET parameter name
705 21 KILIM Ex.: var = GET KPROP
706 35 BANDWIDTH
707 36 FFVEL
708 37 FFACC
709 65 SYNCVFTIME
710-779 130 – 229 GET/SET parameter number
Ex.: var = GET 131
780 — GETVLT/SETVLT parameter number
Ex.: var = GETVLT 780
795-799 130 – 229 GET/SET parameter number
Ex.: var = GET 132
○○ ○ ○○○○
○○ ○ ○○○○
○○ ○ ○○○○
○○ ○ ○○○○
○○○○○○
○○ ○ ○○○○
○○ ○ ○○○○
Parameter 009, 010, 011 and 012 (Display line 1 and 2) has got 5 additional
selections: User parameter 95
[31]
User parameter 96 [32]
User parameter 97 [33]
User parameter 98 [34]
User parameter 99 [35]
Parameter 115 (Slip compensation): Factory setting changed from 100% to 0%.
Factory settings changed:
From to
Parameter 200 Only clockwise 132Hz [0] Both directions 132 Hz [1]
Parameter 203 Min … Max [0] –Max … +Max [1]
Parameter 207 Power dependent 0,05 sec
Parameter 208 Power dependent 0,05 sec
Factory settings:
Parameters 300 - 303, 305 - 308, 314 changed to: ”No operation”
[0]
Parameters 319 + 321 changed to: ”Option 0 … 20mA” [91]
Parameters 323 + 326 changed to: ”Control word bit 11/12” [33]
4 Additional selections in parameters 319+321: Option digital [90]
Option 0 … 20mA [91]
Option 4 … 20mA [92]
Option 0 … 32000 pulses [93]
■■
■■
■ VLT parameters