VLT
®
5000 SyncPos option
MG.10.J4.02 – VLT is a registered Danfoss trade mark
140
30 MENCODER
MENCODER indicates the number of counts of
the master encoders in pulses counts per revo-
lution.
Content
Resolution of encoder 1 (master)
Parameter Group
AXE
Unit
Encoder counts per revolution
Value range
1 … MLONG 500
31 RAMPMIN
The RAMPMIN parameter determines the shortest
ramp (maximum acceleration). It indicates how
long the acceleration phase lasts at the very least
in order to achieve the rated velocity.
NB!
If you work with the SyncPos option card
then you should always set the ramps via
the option card and not in the VLT. The VLT ramps
must always be set to minimum.
Content
Shortest ramp
Parameter Group
AXV
Unit
msec
Value range
1 … 65535 1000
32 RAMPTYPE
RAMPTYPE determines the type of ramp used
(trapeze or sinusoidal).
Content
Ramp type
Parameter Group
AXV
Value range
0 – 1 0
0 = trapeze
1 = sinusoidal
3 3 DFLTVEL
DFLTVEL indicates the default velocity which is
always used when no velocity is defined in the pro-
cess set. This value refers to the
Velocity resolu-Velocity resolu-
Velocity resolu-Velocity resolu-
Velocity resolu-
tion tion
tion tion
tion VELRES (22).
Content
Default velocity
Parameter Group
AXV
Unit
1
/
VELRES;
Standard =
1
/
100
= %
Value range
1 … VELRES 50
Parameter Reference

Table of Contents

Other manuals for Danfoss VLT 5000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 5000 Series and is the answer not in the manual?

Danfoss VLT 5000 Series Specifications

General IconGeneral
BrandDanfoss
ModelVLT 5000 Series
CategoryDC Drives
LanguageEnglish

Related product manuals