12 Application Examples
The examples in this section are intended as a quick
reference for common applications.
Parameter settings are the regional default values
unless otherwise indicated (selected in
parameter 0-03 Regional Settings).
Parameters associated with the terminals and
their settings are shown next to the drawings.
Switch settings for analog terminals A53 or A54
are shown where required.
For STO, a jumper wire may be required between
terminal 12 and terminal 37 when using factory
default programming values.
12.1 Wiring Congurations for Automatic
Motor Adaptation (AMA)
Parameters
FC
+24 V
+24 V
D IN
D IN
D IN
COM
D IN
D IN
D IN
D IN
+10 V
A IN
A IN
COM
A OUT
COM
12
13
18
19
20
27
29
32
33
37
50
53
54
55
42
39
130BB929.10
Function Setting
Parameter 1-29
Automatic Motor
Adaptation
(AMA)
[1] Enable
complete AMA
Parameter 5-12 T
erminal 27
Digital Input
[2]* Coast
inverse
*=Default value
Notes/comments: Set
parameter group 1-2* Motor
Data according to motor
nameplate.
Table 12.1 Wiring Conguration for AMA with T27 Connected
Parameters
FC
+24 V
+24 V
D IN
D IN
D IN
COM
D IN
D IN
D IN
D IN
+10 V
A IN
A IN
COM
A OUT
COM
12
13
18
19
20
27
29
32
33
37
50
53
54
55
42
39
130BB930.10
Function Setting
Parameter 1-29
Automatic Motor
Adaptation
(AMA)
[1] Enable
complete AMA
Parameter 5-12 T
erminal 27
Digital Input
[0] No
operation
*=Default value
Notes/comments: Set
parameter group 1-2* Motor
Data according to motor
nameplate.
Table 12.2 Wiring Conguration for AMA without
T27 Connected
12.2
Wiring Congurations for Analog
Speed Reference
Parameters
+10
V
A IN
A IN
COM
A OUT
COM
50
53
54
55
42
39
A53
U - I
0 – 10 V
+
-
e30bb926.11
FC
Function Setting
Parameter 6-10 T
erminal 53 Low
Voltage
0.07 V*
Parameter 6-11 T
erminal 53 High
Voltage
10 V*
Parameter 6-14 T
erminal 53 Low
Ref./Feedb. Value
0 RPM
Parameter 6-15 T
erminal 53 High
Ref./Feedb. Value
1500 RPM
*=Default value
Notes/comments:
Table 12.3 Wiring Conguration for Analog Speed Reference
(Voltage)
Application Examples
VLT
®
HVAC Drive FC 102
208 Danfoss A/S © 11/2017 All rights reserved. MG16C302
1212

Table of Contents

Other manuals for Danfoss VLT AHF 005

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AHF 005 and is the answer not in the manual?

Danfoss VLT AHF 005 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AHF 005
CategoryDC Drives
LanguageEnglish

Related product manuals