Programming Guide | VLT® AutomationDrive FC 360
Setup: All setups Conversion index: 0
Data type: Uint16 Change during operation: True
The reference signal bypasses the torque controller by an amount as specified.
7-19 Current Controller Rise Time
Default value: Size related Parameter type: Range (15–100%)
Setup: All setups Conversion index: 0
Data type: Uint16 Change during operation: True
Adjust the response time of the current controller relative to the control period.
4.8.3 7-2* Process and Speed Ctrl.
Select the feedback sources for the process PID control, and how this feedback should be handled.
7-20 Process CL Feedback 1 Resource
Default value: [0] No function Parameter type: Option
Setup: All setups Conversion index: –
Data type: Uint8 Change during operation: True
The effective feedback signal is made up of the sum of up to 2 different input signals. Select which input is treated as the source of the
1st of these signals. The 2nd input signal is defined in parameter 7-22 Process CL Feedback 2 Resource.
Option Name
[0] No function
[1] Analog Input 53
[2] Analog Input 54
[3] Frequency input 29
[4] Frequency input 33
7-22 Process CL Feedback 2 Resource
Default value: [0] No function Parameter type: Option
Setup: All setups Conversion index: –
Data type: Uint8 Change during operation: True
The effective feedback signal is made up of the sum of up to 2 different input signals. Select which input is treated as the source of the
2nd of these signals. The 1st input signal is defined in parameter 7-22 Process CL Feedback 2 Resource.
Option Name
[0] No function
[1] Analog Input 53