Programming Guide | VLT® AutomationDrive FC 360
The analog inputs are used for controlling various functions of the drive.
There are 2 types of analog inputs:
l Current input: 0–20 mA and 4–20 mA.
l Voltage input: 0–10 V DC.
Analog outputs
The analog outputs can supply a signal of 0–20 mA or 4–20 mA.
Automatic motor adaptation, AMA
The AMA algorithm determines the electrical parameters for the connected motor at standstill.
Brake resistor
The brake resistor is a module capable of absorbing the brake power generated in regenerative braking. This regenerative brake power
increases the DC-link voltage and a brake chopper ensures that the power is transmitted to the brake resistor.
CT characteristics
Constant torque characteristics used for all applications such as conveyor belts, displacement pumps, and cranes.
Digital inputs
The digital inputs can be used for controlling various functions of the drive.
Digital outputs
The drive features 2 solid-state outputs that can supply a 24 V DC (maximum 40 mA) signal.
ETR
Electronic thermal relay is a thermal load calculation based on present load and time. Its purpose is to estimate the motor temperature.
FC standard bus
Includes RS485 bus with FC protocol or MC protocol. See parameter 8-30 Protocol.
Initializing
If initializing is carried out (parameter 14-22 Operation Mode), the drive returns to the default setting.
Intermittent duty cycle
An intermittent duty rating refers to a sequence of duty cycles. Each cycle consists of an on-load and an off-load period. The operation
can be either periodic duty or non-periodic duty.
LCP
The local control panel makes up a complete interface for control and programming of the drive. The LCP is detachable. With the
installation kit option, the LCP can be installed up to 3 m (9.8 ft) from the drive in a front panel.
GLCP
The graphic local control panel interface for control and programming of the drive. The display is graphic and the panel is used to show
process values. The GLCP has storing and copy functions.
NLCP
The numerical local control panel interface for control and programming of the drive. The display is numerical and the panel is used to
show process values. The NLCP has storing and copy functions.
lsb
Danfoss A/S © 2024.01 AU275649936274en-001401 / 130R0507 | 333

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 360

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 360 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 360 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 360
CategoryDC Drives
LanguageEnglish

Related product manuals