Enter Configuration
Exit and Save Configuration
Ì$+;Î
16-KEY DK MODEL PARAMETERS
Ì$-?Î
154
OPERATIVE MODE
MODE SELECTION
This feature allows the PowerScan PM8300-DK to operate in one of two basic operative modes:
SDIM (Simple Data Input Mode)data entered, either on the keypad or read via
barcode, is transmitted the host once the enter key is pressed, following the
formatting rules described in the previous paragraph.
QTY/CODE (Quantity/Code Mode)Refer to the next section, QTY/CODE MODE
PARAMETERS.
Simple Data Input
Mode
Quantity/Code Mode
ENTER KEY CONFIGURATION
This command is active only when the scanner is in Simple Data Input Mode. It defines the
behavior of the enter key when no data has been previously entered. By default an error sound
is generated; it can also be configured to transmit a "null" character.
Generate error sound
send null char