Product Reference Guide
131
Standard 2 of 5 Set Length 1
This feature specifies one of the bar code lengths for Standard 2 of 5 Length
Control. Length 1 is the minimum label length if in Variable Length Mode, or
the first fixed length if in Fixed Length Mode. Length includes the bar code’s
check and data characters. The length can be
set from 1 to 50 characters.
Table 10 provides some examples for setting Length 1. See page 281 if you
want detailed instructions on setting this feature.
Table 10. Standard 2 of 5 Length 1 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
01 Character 07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT STANDARD 2 OF 5 LENGTH 1 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘1’ ‘0’ and ‘7’ ‘1’ and ‘5 ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
$CS2L1
Select Standard 2 of 5 Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
~
CANCEL
DEFAULT
08 = Length 1 is 8 Characters

Table of Contents

Other manuals for Datalogic PowerScan PBT950X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PBT950X and is the answer not in the manual?

Datalogic PowerScan PBT950X Specifications

General IconGeneral
BrandDatalogic
ModelPowerScan PBT950X
CategoryBarcode Reader
LanguageEnglish

Related product manuals