Enter/Exit Programming Mode
50 QuickScan™ I QD24XX/QBT24XX/QM24XX
USB-OEM Device Usage
The USB-OEM protocol allows for the reader to be identified as one of two different types of bar
code scanners. Depending on what other scanners you may already have connected to a USB-
OEM POS, you may need to change this setting to enable all devices to communicate.
Options are:
Table Top Scanner
Handheld Scanner
$CIBUT00(CR)
USB-OEM Device Usage = Table Top Scanner
$CIBUT01(CR)
USB-OEM Device Usage = Handheld Scanner
DEFAULT
It may be necessary to switch device usage when connecting two readers/scanners of
the same type to a POS system.
USB Interface Options
DEFAULT
$CIFIH00(CR)
Obey Scanner Configuration Host Commands
$CIFIH01(CR)
Ignore Scanner Configuration Host Commands
This feature provides for an interface-specific control mechanism.