USB-OEM Interface Enter/Exit Programming Mode
Product Reference Guide
51
Transmit Labels in Code 39 Format
This feature enable/disables translation to Code 39 before transmitting label data to a USB-
OEM host. Only the symbology identifier is modified for the translation. The data is not con-
verted to Code 39 or verified to be valid for Code
39.
Options are:
IBM Standard Format:
Send labels in standard IBM format.
Mixed IBM Standard and Code 39 Format:
Code 39 Format:
Translate the following symbologies to Code 39:
USB-OEM: Code128, Code 93, and Codabar
DEFAULT
$CIBC300(CR)
Transmit Labels in Code 39 Format =
IBM Standard Format
$CIBC301(CR)
Transmit Labels in Code 39 Format =
Mixed IBM Standard and Code 39 format
$CIBC302(CR)
Transmit Labels in Code 39 Format =
All Code 39 Format

Table of Contents