Reading Parameters Enter/Exit Programming Mode
Product Reference Guide
81
Flash Off Time
This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable
range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. See
page 259 in “References” for detailed information on setting this feature.
$CSNFF
Select Flash OFF Time Setting
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at
left followed by the digits from the Alphanumeric char-
acters in
Appendix D, Keypad
representing your
desired character(s). End by scanning the ENTER/EXIT
bar code again.
Make a mistake? Scan the CANCEL bar code to abort and
not save
t
he entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
06 = Flash is OFF for 600ms
Aiming Pointer
Enables/disables the aiming pointer for all symbologies.
$CTAAP00(CR)
Aiming Pointer = Disable
$CTAAP01(CR)
Aiming Pointer = Enable
DEFAULT

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan QM24 Series and is the answer not in the manual?

Datalogic QuickScan QM24 Series Specifications

General IconGeneral
BrandDatalogic
ModelQuickScan QM24 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals