Operating and storage environment
This table lists the operating and storage specifications of your OptiPlex Small Form Factor 7020.
Airborne contaminant level: G1 as defined by ISA-S71.04-1985
Table 25. Computer environment
Description Operating Storage
Temperature range
10°C to 35°C (50°F to 95°F) -40°C to 65°C (-40°F to 149°F)
Relative humidity (maximum)
20% to 80% (non-condensing, Max dew
point temperature = 26°C)
5% to 95% (non-condensing, Max dew
point temperature = 33°C)
Vibration (maximum)
*
0.26 GRMS random at 5 Hz to 350 Hz 1.37 GRMS random at 5 Hz to 350 Hz
Shock (maximum)
Bottom half-sine pulse with a change in
velocity of 50.8 cm/sec (20 in./sec)
105G half-sine pulse with a change in
velocity of 133 cm/sec (52.5 in./sec)
Altitude range
-15.2 m to 3048 m (-49.8 ft to 10,000 ft) -15.2 m to 10,668 m (-49.8 ft to 35,000
ft)
Airborne Contaminants ISA-71 G1**: <300A/month copper
coupon corrosion AND <200A/month of
silver coupon corrosion
ISA-71 G1**: <300A/month copper
coupon corrosion AND <200A/month of
silver coupon corrosion
]
CAUTION: Operating and storage temperature ranges may differ among components, so operating or storing
the device outside these ranges may impact the performance of specific components.
* Measured using a random vibration spectrum that simulates user environment.
† Measured using a 2 ms half-sine pulse.
Specifications of OptiPlex Small Form Factor 7020
29
Restricted - Confidential