System-diagnostic lights
Table 44. Diagnostic LED behavior
Blinking pattern
Problem descriptionAmber White
1 1 TPM Detection Failure
1 2 Unrecoverable SPI Flash Failure
1 3 Short in hinge cable tripped OCP1
1 4 Short in hinge cable tripped OCP2
1 5 EC unable to program i-Fuse
1 6
Generic catch-all for ungraceful EC code
flow errors
1 7
Non-RPMC Flash on Boot Guard fused
system
2 1 CPU failure
2 2
Motherboard, covers BIOS
corruption or ROM error
2 3 No Memory/RAM detected
2 4 Memory/RAM failure
2 5 Invalid memory installed
2 6 Motherboard/Chipset Error
2 7 LCD failure - SBIOS message
2 8 Motherboard - EC detection of LCD
power rail failure
3 1 CMOS battery failure
3 2 PCI of Video card/chip failure
3 3 Recovery Image not found
3 4 Recovery image found but not valid
3 5 EC ran into power sequencing failure
3 6 Flash corruption detected by SBIOS
3 7 Timeout waiting on ME to reply to HECI
message
4 1 Memory DIMM power rail failure
4 2 CPU Power Cable Connection Issue
Wiederherstellen des Betriebssystems
Wenn das Betriebssystem auf Ihrem Computer auch nach mehreren Versuchen nicht gestartet werden kann, wird automatisch
Dell SupportAssist OS Recovery gestartet.
Bei Dell SupportAssist OS Recovery handelt es sich um ein eigenständiges Tool, das auf allen Dell Computern mit Windows
vorinstalliert ist. Es besteht aus Tools für die Diagnose und Behebung von Fehlern, die möglicherweise vor dem Starten
Fehlerbehebung