Using system diagnostics
If you experience a problem with your system, run the system diagnostics before contacting Dell for technical assistance. The purpose of
running system diagnostics is to test your system hardware without using additional equipment or risking data loss. If you are unable to x
the problem yourself, service and support personnel can use the diagnostics results to help you solve the problem.
Dell Embedded System Diagnostics
NOTE: The Dell Embedded System Diagnostics is also known as Enhanced Pre-boot System Assessment (ePSA) diagnostics.
The Embedded System Diagnostics provides a set of options for particular device groups or devices allowing you to:
Run tests automatically or in an interactive mode
Repeat tests
Display or save test results
Run thorough tests to introduce additional test options to provide extra information about the failed device(s)
View status messages that inform you if tests are completed successfully
View error messages that inform you of problems encountered during testing
Running the Embedded System Diagnostics from Boot
Manager
Run the Embedded System Diagnostics (ePSA) if your system does not boot.
1 When the system is booting, press F11.
2 Use the up arrow and down arrow keys to select System Utilities > Launch Diagnostics.
3 Alternatively, when the system is booting, press F10, select Hardware Diagnostics > Run Hardware Diagnostics.
The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The diagnostics starts
executing the tests on all the detected devices.
Running the Embedded System Diagnostics from the Dell
Lifecycle Controller
1 As the system boots, press F10.
2 Select Hardware Diagnostics Run Hardware Diagnostics.
The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The diagnostics starts
executing the tests on all the detected devices.
7
202 Using system diagnostics

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge R740xd and is the answer not in the manual?

Dell PowerEdge R740xd Specifications

General IconGeneral
Processor cache22 MB
Processor model4216
Execute Disable BitYes
Processor frequency2.1 GHz
Processor manufacturerIntel
Processor boost frequency3.2 GHz
On-board graphics card-
Memory slots24
Memory ranking2
Internal memory16 GB
Buffered memory typeRegistered (buffered)
Internal memory typeDDR4-SDRAM
Maximum internal memory192 GB
HDD size2.5 \
HDD speed10000 RPM
HDD interfaceSerial Attached SCSI (SAS)
Optical drive typeNo
Total storage capacity1800 GB
Maximum storage capacity- TB
Number of HDDs installed1
Supported RAID controllersPERC H740P 8GB
LAN controllerBroadcom 5720, Broadcom 57412
Cabling technology10/100/1000Base-T(X)
Ethernet interface type10 Gigabit Ethernet, Gigabit Ethernet
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Ethernet LAN (RJ-45) ports4
Chassis typeRack (2U)
Product colorBlack
Compatible operating systems- Canonical Ubuntu LTS - Citrix XenServer - Microsoft Windows Server with Hyper-V - Red Hat Enterprise Linux - SUSE Linux Enterprise Server - VMware ESXi
Power supply750 W
CertificationCE, CCC, BIS
Operating altitude0 - 3048 m
Non-operating altitude0 - 12000 m
Storage temperature (T-T)-40 - 65 °C
Operating temperature (T-T)10 - 35 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)10 - 80 %