EasyManuals Logo

Dell PowerEdge R740xd Service Manual

Dell PowerEdge R740xd
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #75 background imageLoading...
Page #75 background image
Removing the air shroud
Prerequisites
CAUTION: Never operate your system with the air shroud removed. The system may get overheated quickly, resulting in
shutdown of the system and loss of data.
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3 If installed, remove the full length PCIe cards.
4 If applicable, remove the GPU cards.
5 If NVDIMM-N battery is installed, disconnect the cables from the NVDIMM-N battery.
CAUTION: NVDIMM-N battery is not hot swappable. To prevent data loss and potential damage to your system, ensure
that your system, LEDs on system, LEDs on NVDIMM-N and LEDs on NVDIMM-N battery are turned o before
disconnecting the NVDIMM-N battery cables.
Step
Hold the air shroud at both ends and lift it away from the system.
Figure 25. Removing air shroud
Next step
If applicable, install the air shroud.
Related link
Removing the expansion card from expansion card riser
Installing the air shroud
Installing the air shroud
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 If applicable, route the cables inside the system along the system wall and secure the cables by using the cable latch.
Installing and removing system components
75

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge R740xd and is the answer not in the manual?

Dell PowerEdge R740xd Specifications

General IconGeneral
Processor cache22 MB
Processor model4216
Execute Disable BitYes
Processor frequency2.1 GHz
Processor manufacturerIntel
Processor boost frequency3.2 GHz
On-board graphics card-
Memory slots24
Memory ranking2
Internal memory16 GB
Buffered memory typeRegistered (buffered)
Internal memory typeDDR4-SDRAM
Maximum internal memory192 GB
HDD size2.5 \
HDD speed10000 RPM
HDD interfaceSerial Attached SCSI (SAS)
Optical drive typeNo
Total storage capacity1800 GB
Maximum storage capacity- TB
Number of HDDs installed1
Supported RAID controllersPERC H740P 8GB
LAN controllerBroadcom 5720, Broadcom 57412
Cabling technology10/100/1000Base-T(X)
Ethernet interface type10 Gigabit Ethernet, Gigabit Ethernet
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Ethernet LAN (RJ-45) ports4
Chassis typeRack (2U)
Product colorBlack
Compatible operating systems- Canonical Ubuntu LTS - Citrix XenServer - Microsoft Windows Server with Hyper-V - Red Hat Enterprise Linux - SUSE Linux Enterprise Server - VMware ESXi
Power supply750 W
CertificationCE, CCC, BIS
Operating altitude0 - 3048 m
Non-operating altitude0 - 12000 m
Storage temperature (T-T)-40 - 65 °C
Operating temperature (T-T)10 - 35 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)10 - 80 %
Weight and Dimensions IconWeight and Dimensions
Width- mm
Height86.8 mm